Fonestar PROX-120S

645.82

amplifikator PA single zone

In stock

SKU: PROX-120S
Categories: ,
Characteristics:
Share:
Description
Specifications
Description
  • PA amplifier
  • The best tool for venue sound installation.
  • Reliable for long working days.
  • Distributed audio for PA installations with 100 V loudspeakers, also with low impedance output.
  • User-friendly operation and a modern, discreet design.
  • A solution to suit any budget.
  • Safe and durable connections with low maintenance.
  • Perfect for public address and piped music systems with 100 V or low impedance line speakers. Retail, educational centres, monuments, exhibitions, bars, restaurants, etc.
Specifications
FEATURES:PA Amplifier Microphone inputs with mix, gain and priority level control. Input priorities by signal level. Tone controls. 100 V and 4 Ω outputs.
POWER:120 W RMS
RESPONSE:40-20,000 Hz (-10 dB)
DISTORTION:THD+N: < 1% @ 1 kHz
S/N RATIO:>77 dB
PROTECTIONS:Overcurrent, DC and short-circuit at the output
INPUTS:CH 1 balanced mic/line with 48V Phantom, Combo connector (XLR + 6.3mm) and euroblock CH 2 and 3 mic/line balanced with 48V Phantom. Euroblock connector Mic signal level: 6 mV RMS (-44 dBV) / 600 Ω Line signal level: 250 mV RMS (-12 dBV) / 100k Ω 2 AUX. 2 x RCA and euroblock connector. Signal level 300 mV RMS (-10 dBV) / 47,000 Ω 1 emergency. Euroblock connector. Signal level loudspeaker line 100 V 1 Mute (Emergency Priority) by contact closure. Euroblock connector
OUTPUTS:1 line. 2 x RCA connector. 1.25 V RMS (+2 dBV) signal level 100 V or 4 Ω speaker output. Connector screw terminals
IMPEDANCE:4 Ω and 100 V line (83 Ω)
FUNCTIONS:Input priority (Voice over VOX inputs): 100V Emergency input with highest priority, attenuates all other inputs. Mute by contact closure, attenuates all inputs except the 100V Emergency input. Channel 1 with priority over all other inputs, level selectable. Channel 2 and 3 with priority over auxiliary inputs, level selectable. Other functions: Power on, protection, signal peak and output signal indicators. Temperature-controlled cooling by forced ventilation
CONTROLS:Microphone volume Mic/line/phantom selector Master volume Aux input selector Tone: bass and treble (+/- 10 dB 100 Hz and 10k Hz) Microphone gain Priority activation signal level (VOX)
OPERATING TEMPERATURE:Operation: 0º ~ 40ºC
MAXIMUM HUMIDITY:95%
POWER SUPPLY:230/115 V AC 50-60 Hz, 320 W Fuse AC 230 V 3.15 A / 115 V 6 A
DIMENSIONS:433 x 89 x 360 mm depth. 2 U 19” rack
WEIGHT:9.5 kg
ACCESSORIES:Power cable Rack mounts